Saturday, August 10, 2019

function of timer in frost free refrigerator

There are many separate components in a refrigerator's defrost system that must work in concert for a frost free system to work properly. We will attempt to explain the workings using simplified electrical schematics.
The heart of the defrost system is the defrost control. The most common control is a mechanical defrost timer which is a motorized device that opens and closes several electrical contacts. Each contact can be thought of as a simple light switch but instead of a light, one connects the defrost heater circuit, another connects the cooling system. When one of these is switched on, the other is switched off. A motor on the timer (NOT illustrated) turns a cam that opens and closes these contacts at set intervals (see below for other types).
Cooling Cycle
Refrigerator cycling on thermostat (cold control)
During the cooling mode, the defrost timer closes a contact to the compressor circuit so it will run. The circuit to the defrost heater is open.
While in this mode, the thermostat (a.k.a. cold control) cycles the compressor and fan motors on and off to maintain an appropriate temperature.

How To Test the Defrost Timer

A mechanical defrost timer controls the defrost cycle of the freezer. In older models, the timer runs continuously and roughly every six hours, cuts power to the cooling system and sends power to the defrost heater. In newer models the timer advances only while the compressor or defrost cycle is running - an improvement for efficiency. As the timer continues to advance, power to the heating element is cut and power is restored to the cooling system. If the timer does not advance, the appliance will be stuck either in defrost or refrigerate mode, resulting in, respectively, no cooling or frost build-up.
Caution: Please read our safety information before attempting any testing or repairs.
 Before testing the defrost timer, unplug the refrigerator to avoid an electrical shock hazard.
The defrost timer is usually found behind the front grill "toe kick" of the refrigerator. It may also be found behind a cover plate inside the refrigerator or freezer, in the temperature control console, or behind the refrigerator near the compressor.
To test whether the defrost timer is simply failing to advance, locate the advance screw and turn it clockwise until you hear it click. This advances it to the next mode. If it was cooling before, it is now in defrost mode. Simply wait about 35 minutes and check whether it has left defrost mode and has resumed cooling (listen for the compressor). If it does not advance, the timer motor is probably bad and the entire timer needs to be replaced. If it advances as it should, then you can follow the steps below to test the switch electrically.
The timer is usually held in place with one or more screws. Remove the screws and gently pull the timer out far enough to disconnect the wiring connector. The connector can be removed by firmly pulling and rocking it left and right. It is not necessary to note the position of the wires because the connector plug is keyed so that it can be replaced in only one way.

Relays Motor Compressor


A hermetic compressor motor relay is an automatic switching device designed to disconnect the motor start winding after the motor has come up to running speed. The two types of motor relays used in refrigeration and air-conditioning compressors are the current and the potential type.




The current-type relay
 is most often used with small refrigeration compressors up to 1 hp. Where power is applied to the compressor motor, the relay solenoid coil attracts the relay armature upward. This causes bridging contact and stationary contact to engage (see Fig. 7-30). This energizes the motor start winding. When the compressor motor comes up to running speed, the motor’s main winding current is such that the relay solenoid coil de-energizes. This allows the relay contacts to drop open, which disconnects the motor start winding.
One thing to remember about this type of relay is its mounting. It should be mounted in a true vertical position so that the armature and bridging contact will drop free when the relay solenoid is de-energized.


Sunday, July 21, 2019

ការជ្រើសរើសទីតាំងសំរាប់ដំឡើងម៉ាស៊ីនត្រជាក់ ( Selection location of Air conditioner for installation)

Installation Air conditioner, (ការដំឡើងម៉ាស៊ីនត្រជាក់)
 

        មុននឹងធ្វើការដំឡើងម៉ាស៊ីនត្រជាក់ ជាងបច្ចេកទេស ត្រូវគិតលើចំនុចមួយចំនួនដូចខាងក្រោម ជាមុខសិនជៀសវាង ការខាតពេលវេលានឹង ពេលខ្លះត្រូវចំណាយប្រាក់កាស ទៀតផង


  1. ការជ្រើសរើសទីតាំង 
      ការជ្រើសទីតាំងត្រូវ ត្រឹមត្រូវ ជាពិសេសទៅតាមការចង់បានរបស់ម្ចាស់ផ្ទះផ្ទាល់ ។ ការរើសទីតាំងល្អគឺមានដូចជា ចំពោះកំណាត់ 
  • ការជ្រើសរើសទីតាំង កំណាត់ខាងក្នុងផ្ទះ (Location of Indoor Unit) 
  1.  ទីតាំងនៃការដំឡើងប្រាកដថា ផ្ទៃខាងមុខមិនមានខ្យល់បាំង
  2. ចំងាយពី កំណាត់ខាងមុខ និងខាង ក្រៅមិនលើងពី ៥- ៧ ម៉ែត្រ (បើលើសនឹងត្រូវធ្វើការថែមសារធាតុធ្វើអោយជ្រជាក់ នឹងមើលការណែនាំរបស់សៀវភៅនែនាំ)។
  3. ជញ្ជាំងដែលបាច់ត្រូវប្រាកដថារឹងមាំ
  4. មិនជាប់ផ្ទាល់នឹងពន្លឺព្រះអាទិត្យ
  5. ទីតាំងងាយក្នុងការរត់ទុយោបង្ហូរទឹក
  6. ត្រូវដំឡើងអោយឆ្ងាយពីអំពូល ជាពិសេសមិនត្រូវ ដំឡើងកំណាត់នេះនៅជាប់ទីតាំងដែលមានកំដៅ ចេញបាញ់ដាក់វា 
  7. មិនត្រូវដំឡើងជិតនឹង ទូរទស្សន៏ 
  8. និងមានច្រើនចំនុចទៀត ទៅតាមការងារជាក់ស្តែង ............



  • ការជ្រើសរើសទីតាំងកំណាត់ខាងក្រៅផ្ទះ(Location of Out door Unit)
  1. ផ្ទៃជញ្ជាំងត្រូវរឹង នឹងមាំ​ ព្រោះថាកំណាតើនេះមានការលំញ័យខ្លាំង នឹងមានសំឡេង
  2. បើអាចកំណាត់នេះត្រូវរកទីតាំងដែលមិនត្រូវ នឹងពន្លឺព្រះអាទិត្យ
  3. កំណាត់ត្រូវដំឡើងនៅទាបជាងកំណាត់ ខាងក្នុងផ្ទះ (បើខ្ពស់ជាងទុយោត្រូវធ្វើ គន្លាក់សំរាប់ការងារត្រឡប់នៃប្រេងចូលម៉ូទ័រ កុមប្រេស័រ)
  4. កំណាត់នេះត្រូវប្រាកដថា មិនត្រូវដំឡើងអោយឆ្ងាយពី ផ្ទះដែលនៅជិតខាងពីព្រោះវារំខាន់ដល់គេនៅក្បែរ ។
  5. ត្រូវដំឡើងរកទីតាំងដែល​ងាយស្រួសជួសជុល ថែទាំ


មានការខ្វះខាត នឹងរិះគន់កែលំអរសូម ផ្តល់យោបលខាងក្រោម 
ឬតាម Tel : 015758554, email: acvuthy@gmail.com

សូមអរគុណ 

Im Vuthy 



Wednesday, July 10, 2019

How to convert kW to BTU/hr



រូបមន្តខាងក្រោមអាចធញវើការគណនាការបំលែងទៅវិញទៅមកបាន
This formula for Convert KW to BTU/hr


How to convert kW to BTU/hr
1 kW = 3412.142 BTU/hr
The power conversion of kW to BTUIT/hr is given by the formula:
P(BTU/hr) = 3412.142 P(kW)

Example
Convert 5kW to BTU/hr:
P(BTU/hr) = 3412.142 5kW = 17060.71 BTU/hr


___________________________

1-  Kilowatts to BTU/hr conversion table(សំរាប់បំបែកពី KW ទៅ BTU)
Power (kW) Power (BTU/hr)
1 kW 3412.142 BTU/hr
10 kW 34121.420 BTU/hr
100 kW 341214.200 BTU/hr
1000 kW 3412142.000 BTU/hr
10000 kW 34121420.000 BTU/hr

__________________________________

2-  How to convert BTU/hr to kW(សំរាប់បំបែកពី BTUទៅKW)

1 BTU/hr = 0.00029307107 kW
So the power conversion of kW to BTUIT/hr is given by the formula:
P(kW) = P(BTU/hr) / 3412.142

Example
Convert 20000 BTU/hr to kilowatts:
P(kW) = 20000 BTU/hr / 3412.142 = 5.861kW

BTU/hr to kilowatts conversion table

Power (BTU/hr) Power (kW)
1 BTU/hr 0.000293071 kW
10 BTU/hr 0.002930710 kW
100 BTU/hr 0.029307104 kW
1000 BTU/hr 0.293071039 kW
10000 BTU/hr 2.930710387 kW


ឬអាច អានលំអិត ខាងក្រោម 
https://www.rapidtables.com/convert/power/kW_to_BTU.html

Monday, July 8, 2019

Room calculation of Air conditioner




Ok..this time i want share the simple basic of calculation how to sizing the air-conditioner.This is a critical part to ensure our selection is suitable with our requirement for room or any space that we want to cooling.
We must calculate the total heat for that room in unit Btu/hr.From this we can convert Btu/hr to air-conditioner size in horse power ( Hp ).We can estimate the size depend on horse power ( hp ).
Total heat calculation ( Btu/hr ) :
1) Measure your room or space area ( width x length ).Use a metric unit for measurement ( meter ).Multiply with 700 to get in Btu/hr
Example : Room area = 10 meter x 6 meter = 60 m2
Btu/hr = 60 x 700 = 42,000 Btu/hr
2) Estimate occupant for this room.multiply with 500 to get in Btu/hr
Example : 5 peoples x 500 = 2500 Btu/hr
3) Estimate the heat from electrical equipments such as lighting,television,computer,fax machine,radio or etc.Refer wattage for equipment and multiply with 3.5
Example : TV = 100 watt, Computer : 200 watt, lighting : 150 watt ; Total : 450 watt
so 450 watt x 3.5 = 1575 Btu/hr
4) So we add all answer to get a total Btu/hr.
Example : 42,000 Btu/hr + 2,500 Btu/hr + 1,575 Btu/hr = 46,075 Btu/hr
5) To get air-conditioner sizing, we must divide Total heat ( Btu/hr) with 9800 Btu/hr
* This value is depend on cooling capacity for each air-conditioner due to efficiency of compressor.It maybe 9,800 btu/hr,10,000 btu/hr or 12,000 btu/hr
Example : 46,075 / 9800 = 4.7 hp
6) From this answer we can estimate to choose a 5 Hp of air-conditioner for our room.
If you not sure to calculate air-conditioner size for your room,Please contact your local HVAC expert and the will calculate and advice the suitable size and types of air-conditioner for you.
This calculation is just for estimation value.It not absolute answer for your air-conditioner sizing.You can make a comparison your estimate air-conditioner size with your local HVAC expert.I hope this information
can help all of you how to sizing the air-conditioner to avoid unnecessary cost.
- See more at: http://www.electricneutron.com/air-condition/air-conditioner-sizing/#sthash.JaoOFu6R.dpuf

ការគណនាទំហំម៉ាស៊ីត្រជាក់


ការគណនាសំរាប់ទំហំម៉ាស៊ីត្រជាក់




ម៉ាស៊ីនត្រជាក់  គឺជាឧបករណ៏មួយប្រភេទដែលត្រូវបានគេប្រើប្រាស់វា​   យ៉ាងទូលំទូលាយសំរាប់ផ្តល់ភាពត្រជាក់ទៅដល់ក្នុងបន្ទប់ ការិយាល័យ លំនៅដ្ឋាន ឬកន្លែងនានា    ម៉ាស៊ីនត្រជាក់មានច្រើនប្រភេទ និងច្រើនទំហំ ដោយផ្អែកទៅតាមការផលិតរបស់រោងចក្រដែលបានផលិតមក ​ប្រើទៅតាមទីកន្លែង  និងមាឌនៃ បន្ទប់។​
នៅពេលដែលធ្វើការដំឡើងចាំបាច់ណាស់គឺយើងចង់បានភាពត្រជាក់គ្រប់គ្រាន់ដល់បន្ទប់របស់យើង  ។​  ការធ្វើការគណនាសំរាប់ដាក់ម៉ាស៊ីនត្រជានេះមានការសំខាន់ណាស់ ​ពីព្រោះថាបើយើង ​បានជ្រើសរើសម៉ាស៊ូនត្រជាក់ដែលមានកំលាំង សម្ថភាពធ្វើការដែលផ្តល់ភាពត្រជាក់បានច្រើន គឺយើងច្បាស់ជាប្រឈបមុខនឹងការ ចំណាយលើតំលៃអគ្គិសនីខ្ពស់  ។ តែផ្ទុយមកវិញបើកាលណាយើងធ្វើកលារជ្រើសរើសយក ម៉ាស៊ីនត្រជាក់ដែល តំលៃបង់ថ្លៃអគ្គិសនីទាប  គឺយើងបានភាពត្រជាក់មិនគ្រប់គ្រាន់ដល់បន្ទប់ ។ ដូចនេះសរុបមកយើងត្រូវធ្វើការគណនា អោយបានភាពត្រឹមត្រូវដើម្បីផ្តល់ភាពត្រឹមត្រូវ ដូចខាងក្រោមនេះ៖
ការគណនាសំរាប់ទំហំម៉ាស៊ីត្រជាក់
ការធ្វើការគណនា​មានវិធីសាស្ត្រច្រើនសំរាប់ធ្វើការគណនាផ្ទៃបន្ទប់ សំរាប់ដាក់ម៉ាស៊ីនត្រជាក់​សំរាប់បានភាពត្រជាក់គ្រប់គ្រាន់ដល់
ផ្ទៃបន្ទប់របស់យើង​ អោយបានត្រឹមត្រូវតាមឧទារណ៏ខាងក្រោមនេះ យើងត្រូវតែធ្វើការគណនាកំដៅសរុបនៅក្នុងផ្ទៃបន្ទប់អោយបានត្រឹមត្រូវ  ដោយគិតជា  BTU/hr អ្នកនឹងអាចដាក់កំលាំងសេះរបស់ម៉ាស៊ីនត្រជាក់ បានដោយផ្អែកលើការគណនានេះ ។ការគណនាកំដៅសរុបក្នុងបន្ទប់
  • ធ្វើការវាស់ផ្ទៃបន្ទប់ដែលត្រូវដំឡើងនោះជាមែត្រការ(m2) ​​​  ដោយយកបណ្តោយនៃបន្ទប់ មកគុណនឹង​  ទទឹង បន្ទប់ ពេលឃើញហើយ យកមកគុណនឹង ៧០០ ដើម្បីបាន១មែត្រការេ បីតីយូក្នុងមួយមោង BTU/hr 
Example :
 ផ្ទៃបន្ទប់ = 10 meter x 6 meter = 60 m2 (មែត្រការេ)
 Btu/hr = 60 x 700 = 42,000 Btu/hr  
  •     ការគណនាចំនួនមនុស្សដែលនៅក្នុងបន្ទប់នេះ ។ ដែលមនុស្សម្នាក់អាចបញ្ចេញបាន ៥០០BTU/hr
Example : 5 peoples x 500 = 2500 Btu/hr
3
  •  ​​​គណនាកំដៅដែលចេញពីគ្រឿងអគ្គិសនីផ្សេងៗ ដែលមានដូចជាៈ   អំពូល ទូរទស្សន៏ ម៉ាស៊ីនកុំព្យួទ័រ  និងគ្រឿងផ្សេងៗទៀតដែលមាន   មកគុណនឹង មេគុណ ៣.៥​​។​
Example : TV = 100 watt, Computer : 200 watt, lighting : 150 watt ; Total : 450 watt
450 watt x 3.5 = 1575 Btu/hr
  •     សរុបបន្ទុកកំដៅទាំងអស់ខាងលើ
Example : 42,000 Btu/hr + 2,500 Btu/hr + 1,575 Btu/hr = 46,075 Btu/hr
  •    ទំហំនសម៉ាស៊ីនត្រជាក់
ដើម្បីបានទំហំនៃម៉ាស៊ីនត្រជាក់យើងត្រូវយកតំលៃកំដៅសរុបដែលបានពីការគណនាខាងលើមកចែកកំលាំម៉ាស៊ីនត្រជា់ក់ក្នុងមួយសេះដែលជាទូទៅ ១សេះគឺ ៩០០០BTU/hr ។ ​
Example : 46,075 / 9000 = 4.7 hp
  •     នេះជាចំលើយដែលបានមកពីការគណនា ដូចនេះយើងធ្វើការជ្រើសរើសតាមការគណនានេះ ដោយយោងតាមការផលិតវាមិនមានដូចនេះ យើងយក ៥សេះ(5HP) ។

ដើម្បីប្រាកដច្បាស់សូម ធ្វើការទំនាក់ទំនងមកយើងខ្ញុំ ដើម្បីបានភាពត្រឹមត្រូវក្នុងការដំឡើង យ៉ាងត្រឹមត្រូវបំផុត និង សេវាកម្មល្អដែលមានជាង ប្របកដោយមានសមត្ថភាពពិតប្រាកដ តាមទូរសព្ទ័លេខ 015​758554,  www.acs-engineering.blogspot.com, email: acvuthy@gmail.com

សូមអរគុណ

របៀបវាស់ម៉ូទ័រកង្ហារ២ ល្បឿន

  • ការវាស់រក ល្បឿនម៉ូទ័រកង្ហារកុងដង់ស័រ  Condenser ២ល្បឿន  របស់ម៉ាស៊ីនត្រជាក់
ដើម្បីវាស់វាបានគេត្រូវ ធ្វើការវាស់ កន្ទុយខ្សែរបស់វាដែលមាន ៤កន្ទុយខ្សែ និងមានពណ៏ខ្សែ ផ្សេងៗគ្នា ។ការវាស់នេះមាន ៦ ដង ។     ឧទាហរណ៏ ៖ មានពណ៏ -ផ្កាឈូក/-ពណ័ស/-ត្នោត/-លឿង


  • ១-ការវាស់គឺ ត្រូវមានអូមម៉ែត្រ

ផ្កាឈូក​  វាស់នឹង  -ពណ័ស= ៣២ អូម
ផ្កាឈូក   វាស់នឹង ត្នោត​​   = ៦០អូម
ផ្កាឈូក   វាស់នឹង លឿង    =២០អូម
ត្នោតវាស់នឹង លឿង   =  ៥០អូម
ត្នោតវាស់នឹងពណ័ស  =៣០អូម
ពណ័សវាស់នឹង លឿង   =១០  អូម
  • ២-ការប្រៀបធៀប តំលៃអូម នៃពណ៏ខ្សែនីមួយៗ

យើងត្រូវពីនិត្យមើល តំលៃខ្សែណាដែលមាន  តំលៃអូម ធំជាងគេបង្អស់ នឹង តូចជាងគេបង្អស់
ចំនាំ ៖ 
តំលៃខ្សែពណ៏អូមណាដែលធំបង្អស់នោះគឺខ្សែល្បឿន R និង  S ។  តែមិនដឹងថាមួយណា  Rឬ   S ។ ដូចនេះបើចង់ដឹងថាខ្សែពណ៏ណានៃ  ខ្សែល្បឿន R និង  S ពិតប្រាកដត្រូវ យកមកវាស់ធៀបនឹង ខ្សែពណ៏ ដែលតូចជាងគេបង្អស់ មួយណាក៏បាន  ។  ខ្សែដែលតូចគឹ ពណ័ស នឹង លឿង   =១០  អូម ។បើចឹងយើងយក ខ្សែពណ៏ ស។ បើយកខ្សែមួយណាក៏ឃើញ ដូចគ្នាដែរ ។

រកខ្សែ  R &  S មានពណ៏ ផ្កាឈូក  នឹង ត្នោត​​   = ៦០អូម
ពណ័វាស់នឹង  -ផ្កាឈូក= ៣២ អូម
ពណ៏វាស់នឹងពណ័ ត្នោត =៣០អូម